AOR AR-DV3 SD-card loading
Load the paired channel and bank-name files directly on your DV3, without paid programming software.
Use with AOR AR-DV3Open guideChoose your scanner, software or file type to find the correct loading instructions.
Use the filename or extension from your delivery email. Model-specific files must stay with the scanner selected at checkout.
MEMCH.CSV + MEMBK.CSVAR-DV3 SD card .hpeSentinel HPE .rsfBuTel ARC260 EZ Scan .txtWhistler EZ Scan Scan125 .csvScan125 ARC125 .csvARC125 CSV .rsfARC DV1 RSF memch.csvAOR memory file CHIRP .csvCHIRP CSV .s1bSDRuno bank Generic .csvGeneric CSV Back up, import, check the result and recover your original programming if needed.
Load the paired channel and bank-name files directly on your DV3, without paid programming software.
Use with AOR AR-DV3Open guideImport, review, enable and write a Favorites List with the correct regional Sentinel edition.
Use with SDS100E / SDS200E, UBCD3600XLT and BCD436HP / BCD536HPOpen guideOpen the native RSF project in ARC260, check its service banks and send it to your UK scanner.
Use with UBCD160DN and UBCD260DNOpen guideImport the three supplied columns, assign a scan list and copy the reviewed configuration to the scanner or SD card.
Use with Whistler TRX-1 / TRX-2Open guideUse the tested column map, create Scan125 program data and send it to an analogue UBC125XLT.
Use with UBC125XLT-C and Scan125 Convert CSVOpen guideOpen the generated file in CSV Mapper, copy each 50-memory bank into ARC125 and upload the reviewed result.
Use with ARC125 with UBC125XLT(C), UBC126AT, BC125AT or AE125HOpen guideOpen the named-bank project directly in ARC DV1, review the channels and upload to your AR-DV1 by USB.
Use with ARC DV1 BASIC or PRO with AOR AR-DV1Open guideBack up the receiver-created memory file, review the supplied file and restore it through the receiver's SD-card workflow.
Use with AOR AR-DV1 and AR-DV10Open guideCopy receive-only conventional memories into a radio-specific image, validate its fields and upload safely.
Use with CHIRP-supported radiosOpen guideOpen the supplied memory bank, confirm its frequencies and adapt mode, bandwidth and receiver settings.
Use with SDRunoOpen guideMatch the supplied columns to another conventional-channel importer, test a small batch and preserve a rollback copy.
Use with Other scanner and SDR softwareOpen guideCheck the file type, capacity, required software and important limitations for each model.
A conventional .hpe Favorites List for Uniden x36/SDS Sentinel.
Full loading help: Sentinel HPE importOpen guideA conventional .hpe Favorites List for the UBCD3600XLT Sentinel workflow.
Full loading help: Sentinel HPE importOpen guideA conventional .hpe Favorites List for Uniden BCDx36HP Sentinel.
Full loading help: Sentinel HPE importOpen guideCreate a native ARC260 RSF file for the UK Uniden UBCD160DN, with named banks for your selected services.
Full loading help: BuTel ARC260 RSF loadingOpen guideCreate a native ARC260 RSF file for the UK Uniden UBCD260DN, with named banks for your selected services.
Full loading help: BuTel ARC260 RSF loadingOpen guideAn analogue CSV for Scan125Convert and Scan125 Control.
Full loading help: Scan125Convert and ControlOpen guideA three-column conventional-frequency import file generated automatically for review in Whistler EZ Scan.
Full loading help: Whistler EZ Scan importOpen guideChoose an AOR memch.csv for SD-card loading, or the separate ARC DV1 (.rsf) option for BuTel BASIC or PRO.
Full loading help: AOR SD-card memory loadingOpen guideA native AOR AR-DV10 memory-channel CSV named memch.csv, built around your chosen UK location.
Full loading help: AOR SD-card memory loadingOpen guideDownload channels and service-bank names together, then load them directly from the DV3's SD card.
Full loading help: AR-DV3 SD-card loadingOpen guideInstructions for software and portable file formats rather than a named scanner.
An analogue CSV for the Scan125 conversion workflow.
Full loading help: Scan125Convert and ControlOpen guideA 500-memory analogue CSV for ARC125 CSV Mapper.
Full loading help: ARC125 CSV Mapper importOpen guideOpen a native .rsf project in ARC DV1 BASIC or PRO, with your selected services organised into named banks.
Full loading help: ARC DV1 RSF loadingOpen guideAn analogue, receive-only CHIRP CSV for copying into a supported radio image.
Full loading help: CHIRP CSV importOpen guideAn SDRuno memory bank using the documented .s1b format.
Full loading help: SDRuno memory-bank loadingOpen guideA CSV with FrequencyMHz, Name, Modulation and Type columns.
Full loading help: Generic CSV mappingOpen guideCompare scanners, check frequency groups or recover an earlier purchase.
Compare supported receivers, digital modes, memory limits and important differences before ordering.
Compare receivers and supported file formatsOpen guideSee the source, scope and limitations of WTR, CB, PMR446, amateur, marine, common and airband groups.
Choose only the groups you wantOpen guideRequest a private one-use access link for earlier purchases and reopen their model-specific loading instructions.
Passwordless customer accessOpen guideRead or export the current configuration and keep an untouched copy outside the software's active folder or SD card.
Use the model, extension and software named in the delivery. Renaming HPE, native settings, memory banks or CSV files does not convert them.
Check a few names, frequencies, enabled banks or lists, receive modes and memory limits. A listed channel may not be active.